Site Search
Product Index
Design Assistance

 

 

APPLICATION AND USE
Alpines Fire-Storm Doors are widely used in locations where their exists high winds and high levels of storm weather activity. Throughout the Florida
Coastline and many other coastal locations the Alpine Fire-Storm doors have
proven successful in protecting both people and property from injury do to flying debri.


GENERAL
Manufacture Florida Department Of Community Affairs Fire-Storm doors with
a design pressure of +60 psf & -60 psf, 1.5 Safety factor, 90+/- psf, by Alpine.
Opening preparation, miscellaneous or structural metal work, access doors,
finish or field painting, field electrical wiring, wire, conduit, fuses and disconnect
switches are in the Scope of Work of other divisons or trades.


CURTAIN
Constructed of Interlocking, 2 3/4” Flat Slats: Roll-form galvanized steel G90
coating exterior (G60 interior), Structural Quality Grade C (ASTM A653/A653M) in 22 Gauge. Optional Gauges in 20 and 18. (Finish Options: phosphate, baked enamel or powder coated.)


GALVANIZED ENDLOCKS
Hot dipped galvanized cast iron endlocks and windlocks riveted to the ends of every slat, with (4) four, 1/4” rivets.


BOTTOM BAR
Two galvanized steel angles equipped with vinyl weatherstripping which extends into the guides. Standard finish galvanized as per ASTM A 653/A 653 M.


GUIDES
Guides are designed to meet Florida Department Of Community Affairs specifications using structural angles, ASTM A36. For doors up to 12’-0” WIDE X
30’-0” High, wall angle 3 X 2-1/2 X 1/4”, inside angle 2-1/2 X 2 X 1/4”, outside
angle 3 x 3 x 3/16” min, bolt spacing not more than 15” o/c. For door widths
20’-8” to 30’-0” high, wall angle 3-1/2 x 3-1/2 x 7/16” min, inside angle 2-1/2 x
2/-1/2 x 3/8” min, outside angle 4 x 3 x 1/4” min, bolt spacing not more than 9”
o/c max. (Option: Vinyl Weather Stripping)

COUNTERBALANCE ASSEMBLY
Steel pipe barrel capable of carrying a curtain load with a maximum deflection
of 0.03” per ft. of door width. Heat treated springs encased in a steel pipe
and designed to include an overload factor of 25% to ensure minimum effort
to operate. A sealed and prelubricated ball bearing is present at the rotating
support point. (A torsion spring charge wheel is used for applying spring
torque and for future adjustments). Stainless steel or hot dipped galvanized
pipe assemblies are available. Option: High Cycle Springs can be designed to
satisfy up to 400,000 life cycles.


BRACKETS
Steel plate not less than 1/4” thick with ball bearings at rotating support
points. When bolted to the wall the mounting angle supports the counterbalance
assembly and forms an end enclosure. (Option: Stop Lock Bearing which prevents the door from free falling in the event of a drive operation failure.
HOOD Hexagon (Option: Square or Round) #22 ga. galvanized steel is formed to fit the contour of the brackets. Finish Options: phosphate, baked enamel or powder coated.


FASCIA GALVANIZED (OPTIONAL)
Useful where the area behind the hood is open. Especially applicable to pre-engineered buildings.


OPERATION
Available in push-up, hand chain, hand-crank, or motor operation. For other
optional features see the motor operators section in this catalog.


LOCKING
Provides padlockable slide locks for latching and locking the door on the coil
side of the bottom bar. Electric Interlocks recommended with motorized doors.

FINISH
Slats are prepared with a minimum galvanizing of G-90 (exterior). The hoods are galvanized and other exposed ferrous surfaces are prime painted or powder
coated.


GALVANIZING (OPTION)
To be applied to the guides, brackets, pipe shafts and gears in addition to the standard specifications. Applied where conditions of extreme or unusual atmospheric contamination is present. (In accordance with ASTM A123)


LABEL
Fire Storm Doors have been UL classified and listed under the UL Category, “Products for use in Windstorm-Rated Assemblies - ZHLL”, and were Miami-
Dade County Tested for Protocols, PA-201, PA-202 and PA-203. Alpine Smoke-Fire Doors have been UL Classified and listed under the Product Category : Rolling-Steel Type Fire Doors - GSVV.R. Ratings : 4 HR, 3 HR, 1-1/2 HR, 1 HR or 3/4 HR. Sizes : Classified for openings up to 20’wide X 30’high.

Click Here for UL Labeled Smoke and Draft Control Assemblies

Contact us today to find out which Alpine® solution is right for you!

 
 
 
 
 
 
 
 

  Fire Test

See for yourself how Alpine® Fire Doors handle the heat. Click here for some pictures from one of our recent fire tests.

   
  Powder Coating

Our large selection of colors make our doors decorative and durable.

Standard Colors
View | Download
Special Effects
View | Download


2 3/4" Flat Slat

Double Angle Bottom Bar


Structural Guides
with Windbar

Disclaimer: All data provided on this website is to be used for information purposes only, and is subject to change without prior notice. Alpine shall not be liable for technical or editorial errors or ommisions contained herein, nor for direct, incidental, consequential or any other damages resulting from furnishing, performance, or use of this information, even if Alpine Overhead Doors, Inc. has been advised of the possibility of such damages in advance. See the additional disclaimer in our Terms of Use.