Auto Smoke Fire-Storm® IMB - Insulated Auto-Reset High Wind Smoke Sealed Fire Door
Product Features
- Crossbred fire & storm protection insulated roller doors
- Perimeter smoke seals standard
- Oversize UL label up to 20’x30′
- Built in accordance with the requirements specified by U. L.
- Our hurricane fire shutter is Dade County approved for high wind loads up to 187 mph
- STC rating of 23
Alpine’s Auto Smoke Fire-Storm® IMB Doors are widely used in locations where there exists high winds and high levels of stormy weather activity. Throughout the Florida Coastline and many other coastal locations the Alpine Fire-Storm® doors have proven successful in protecting both people and property from injury do to flying debris.
- Alpine’s Smoke Fire-Storm® IMB Doors are effective, strong, insulated and come in flat interlocking slat designs.
- Smoke seals prevent the spread of smoke.
- Doors can be manually pushed up, hand-crank, hand-chain or motor operated.
- All operators can be adapted to specific conditions.
- Slide locks as a standard are provided.
- Alpine’s rolling steel doors are durable, sturdy and economical to install and maintain.
- STC rating of 23.
The Alpine Advantage and Benefit
- Alpine’s Fire-Storm® doors ensure security and fire protection and are listed and/or classified by:
- Underwriters Laboratories, Inc., (U.L.)
- Underwriter’s Laboratories of Canada, Inc. (U.L.C.)
- Made-To-Order manufacturing process. Alpine builds your product to the exact size specified by you.
- All of our products are constructed to have a rigid and compact design which provides for a more structural grade product while reducing overhead space and obstruction.
- Alpine builds trust by providing our products with a 2-year warranty on material and workmanship. As we also offer an optional five-year pro-rated warranty.
- We are an ISO 9001 registered firm which ensures you that our products are built with true quality you can count on.
FIRE-STORM LABELING
Fire Storm Doors have been UL classified and listed under the UL Category
- Products for use in Windstorm-Rated Assemblies – ZHLL”, Miami-Dade County Tested for Protocols, PA-201, PA-202 and PA-203.
- Alpine Smoke-Fire Doors have been UL Classified and also listed under the product Category: Rolling-Steel Type Fire Doors – GSNV.
- Ratings: 4 HR, 3 HR, 1-1/2 HR, 1 HR or 3/4 HR.
- Sizes: Classified for openings up to 20’wide X 30’high.
- Manufacture Florida Department Of Community Affairs Fire-Storm® Insulated doors with a design pressure of +60 psf & -60 psf, 1.5 Safety factor, 90+/- psf, by Alpine.
- The opening preparation and the installation of the fire door shall be performed in strict compliance with NFPA-80.
- Opening preparation, miscellaneous or structural metal work, access doors, finish or field painting, field electrical wiring, wire, conduit, fuses and disconnect switches are in the Scope of Work of other divisions or trades.
CURTAIN
Constructed of Interlocking, 2 3/4” Flat 7/8” Thick Insulated Slats: Roll-formed galvanized steel, Structural Quality Grade D (ASTM A653/A653M) in 22 Gauge minimum front slat with various back slat combinations
Material Options: Stainless Steel
Finish Options: Finish Coat of Tan, White or Grey; or ExoShield™ Powder Coating.
> Click here for available Powder Coating colors.
LOCKING
Option 1: Slide bolt locks on the bottom bar. (Motorized doors require electric interlocks.)
Option 2: Cylinder locks.
Option 3: Padlockable chain keeper on guides.
HOT DIPPED GALVANIZING (OPTION)
Applied to the guides, brackets and gears in addition to Standard Specifications. Applied where conditions of extreme or unusual atmospheric contamination is present. As per ASTM-A123.
(Pipe Shafts available with Zinc Enriched Powder Coating or Stainless-Steel)
FASCIA (OPTIONAL) – Should this be here??? Not in new writeup.
Useful where the area behind the hood is open, as seen in a between jambs type mounting configuration or other condition that exposes the opposite of coil side. Especially applicable with pre-engineered buildings. Finish is to match curtain.
Alpine® Motor Operators Auto Smoke Fire-Storm® IMB
Click below for full details about operators for automatic releasing doors and fail-safe fire doors:
HAND CHAIN:
The Redi-Reset®-MC Chain
- Suitable for applications up to 180 square feet.
- Closes by gravity in event of fire or smoke alarm when integrated with fire alarm systems.
- Operated up by chain, down by cable. This egress door operator is compatible with standard fusible links, cable, sash chain, and electronic release devices. Visit Release Devices tab above for additional info.
- FM Approved and UL Classified.
- > View Redi-Reset®-MC Details
The Alpine Redi-Reset®-GC
- Suitable for applications up to 122 square feet.
- Closes by gravity in event of fire or smoke alarm when integrated with fire alarm systems. Operated up/down by hand chain. Compatible with standard fusible links, cable, sash chain, and electronic release devices. Visit Release Devices tab above for additional info.
- UL Classified.
- > View Redi-Reset®-GC Details
HAND CRANK:
The Redi-Reset®-MK
- Suitable for applications up to 180 square feet.
- Closes by gravity in event of fire or smoke alarm when integrated with fire alarm systems. Operated up by hand crank, down by cable. Compatible with standard fusible links, cable, sash chain, and electronic release devices. See Visit Release Devices tab above for additional info.
- FM Approved and UL Classified.
- > View Redi-Reset®-MK Details
FAIL-SAFE ELECTRONIC:
Alpine’s Redi-Reset®-FDCL
- Suitable for applications up to 150 square feet.
- Maximum 1/2 HP.
- Wired to heat sensors.
- 72 hour battery backup system. Low battery indicator light. Fail-Safe if battery backup fails door closes automatically. Low battery indicator light. Key switch for easy self testing or for periodic testing by Fire Marshalls. Electric sensing edges are required for the operators for fail-safe fire doors.
- FM Approved and UL Classified.
- > View Redi-Reset®-FDCL Details
Alpine’s Redi-Reset®-FDC
- Suitable for applications up to 350 square feet.
- Maximum 1 HP.
- Wired to heat sensors.
- 72 hour battery backup system. Low battery indicator light. Key switch for easy self testing or for periodic testing by Fire Marshalls. Electric sensing edges are required for this egress door operator.
- FM Approved and UL Classified.
- View Redi-Reset®-FDC Details
Alpine’s Redi-Reset® Model FS
- Suitable for applications up to 1200 square feet.
- Maximum 5 HP.
- Fail-Safe – will close automatically during power outage.
- The operators for fail-safe fire doors are compatible with standard fusible links, cable, sash chain, and electronic release devices. Visit Release Devices tab above for automatic releasing doors. Electric sensing edges are required.
- FM Approved and UL Classified.
- > View Redi-Reset® FS Details
NON FAIL-SAFE ELECTRONIC:
The Alpine Redi-Reset®-NF
- Suitable for applications up to 1200 square feet.
- Maximum 5 HP. Auxilary emergency hand chain up to 2 HP only. Non Fail-Safe – will not close during power outage. Compatible with standard fusible links, cable, sash chain, and electronic release devices. Visit Release Devices tab above for additional info. Electric sensing edges are required for this egress door operator.
- FM Approved and UL Classified.
- > View Redi-Reset®-NF Details
SAFETY ENTRAPMENT PROTECTION
Option: Electric Monitored Sensing edge with a coil cord.
Option: Redi-Reverse™ Light Curtain consists of a 6’0” high light curtain integral to the guides, left and right. If an object passes through the light curtain during the close cycle, the door will reverse to the open cycle and come to rest upon reaching the open limit
Option: Photo safety sensors mounted to the guides 6” above the finished floor that project an infrared beam across the width of the door. Breaking the beam while the door is in motion will result in the immediate stop of downward travel and reverse the door to reopen to the top limit
Auto-Smoke Fire-Storm® IMB Overhead Smoke Doors
Advanced Windstorm Resistant Insulated Fire Doors
Below you will find comprehensive storm door drawing details for our insulated windstorm doors featuring important operation details for using hand chain, hand crank, or motor operation. The AutoCAD drawings and AutoCAD details for the overhead smoke doors comply with 08360, 08400 & 08330 construction specs. The storm door drawing details available for Alpine’s Auto-Smoke Fire-Storm® have several mounting options, including face mounted to steel, masonry, or between jamb mounted.
Alpine’s Smoke Fire-Storm® IMB insulated windstorm doors are high quality doors that are designed to prevent the spread of smoke. The storm door drawing details are Dade County, Florida approved for high winds up to 187mph and Underwriters Laboratories Inc. for fire protection. These overhead smoke doors are a combination of the features of the Redi-Storm®® and Fire-Tite® models.
To download storm door drawing details (PDF), please click below.
For CAD drawings, please click here
- Face Mounted to Masonry
- Face Mounted to Steel
- Between Jamb Mounted
- Not available but may be mounted to I-beam or steel tubes
The Smoke Fire-Storm® AutoCAD storm door drawing details are for informational purposes. They may change at any time. The CAD detail and CAD drawing reflect the options that are available to the architects and engineers compiling an AutoCAD drawing to present to contractors. The AutoCAD detail and AutoCAD drawing will be updated regularly. Alpine’s insulated windstorm doors and overhead smoke doors are built to last.
Disclaimer: All data provided on this website is to be used for information purposes only, and is subject to change without prior notice. Alpine shall not be liable for technical or editorial errors or omissions contained herein, nor for direct, incidental, consequential or any other damages resulting from furnishing, performance, or use of this information, even if Alpine Overhead Doors, Inc. has been advised of the possibility of such damages in advance. See the additional disclaimer in our Terms of Use.
Alpine® Auto Smoke Fire-Storm® IMB Insulated Doors
Windstorm Resistant Fire Doors
> Download Specifications (PDF)
> Download Specifications (DOC)
Model FIRE-STORM® AUTO SMOKE IMB
Flat Slats
Fire-Tite® Rolling Doors
2. Smoke Seal: 1 ½” brush smoke gaskets.
NOTE: For specifications, architects must choose from a variety of options for fire resistant doors. The standard choice will be shown first in plain text followed by the options shown in [brackets] (Example “Finish: Galvanized [Powder coated] [Baked enamel]”). The specifier must make the appropriate choices and delete the others (Example: “Finish: Powder coated”).
Alpine® Redi-Release®
For Use with Fire-Tite®, Fire-Shut® and Fire-Storm® Doors
The Solid State Securities time delay fire door release device is an optional feature for your fire resistant doors. Alpine® Redi-Release® is normally energized as a fail-safe device for fire doors, and incorporates state of the art electronic security control circuitry.
The Redi-Release series release devices are the ideal safety option for fire resistant doors. These devices are able to respond to emergency conditions generated by manual or automatic initiating devices that are normally closed, and are designed to be used in conjunction with a temperature fuse link system. The Test-Release device features include time delay on alarm and power loss, motor voltage sensing, form C output, proximity/door edge input and trouble diagnostic capabilities. Check model label to be installed to verify applicable features.
CAUTION: As with all releasing device systems, maximum fire protection is provided when installed in accordance with factory specifications and used with fuse link systems. Fail-safe operation can only be provided when input power is applied.
LiftMaster Professional
For Motorized Doors – Electro-Mechanical Operators
The AFCB fire door release device is designed to be used in conjunction with a standard commercial door operator to provide a fully automated door closing system. For use with motorized doors incorporating a reversing electric safety edge. This 120VAC device can power up to four smoke detectors and two horn/strobes or speaker/strobes. This system combines state-of-the-art functionality and advanced features typically found on special-order fire door operators.
LM21AFCB – Download Owners Manual
- UL864 Revision 9 compliant
- Programmable DIP switch delay setting – either 10, 20, 30 or 60 seconds delay of door release to permit passage clearance
- Internal battery backup system
- Motor voltage sensing monitors voltage to the operator and activates a mechanical door release upon loss of power to the operator.
- Obstruction cycling – works in conjunction with the door’s electrical safety edge, reversing the door if an obstruction is encountered
- Test keyswitch – permits floor-level testing of the system
Non-Motorized Doors
The XP fire door release device provides a fail-safe release mechanism for non-motorized doors and acts as an interface between the door and the fire alarm system. The device required 24VDC power from an approved UL1481 regulated power supply with battery backup, such as a fire alarm control panel. Therefore, installation will require coordination with a fire panel installer.
LM21XP Download Owners Manual
- UL864 Revision 9 compliant
- Programmable DIP switch delay setting – either 10, 20, 30 or 60 seconds delay of door release to permit passageway clearance
- Close door detection – prevents door release if the door is kept in the closed position and eliminates door reset service calls or potential system damage
- On board diagnostic – LEDs for early troubleshooting
- Testing function – allows routine fire door testing without requiring activation of the central alarm system; easy reset function returns the device to a standby state
Non-Motorized Doors with Battery Backup Option
Versatility allows the XPBB fire door release device to operate on 120VAC, 24VAC or 24VDC power sources. Internal battery backup allows the release device to stand alone from the fire alarm system and act independently in the event of a power outage. The system can provide 24VDC power for up to four smoke detectors and two horn/strobes, mounted on either side of the door. Programmable delay settings, close door detection, diagnostic LEDs, localized testing, and reset capabilities are also standard.
LM21XPBB Download Owners Manuals
- UL864 Revision 9 compliant
- Programmable DIP switch delay setting – either 10, 20, 30 or 60 seconds delay of door release to permit passageway clearance
- Inputs for normally open – 2-wire or 4-wire detectors and 4-wire normally closed detectors
- On board diagnostic – LEDs for early troubleshooting
- Trouble and alarm relays – for communication with the fire alarm control panel, if required
- Audible trouble sounder – to indicate when the release device is not operational
- Testing function – allows routine fire door testing without requiring activation of the smoke detector
Contact us today to find out which Alpine® solution is right for you!
3 and 4 Hour approved fusible link shutters for doors in dividing fire walls with openings not exceeding 152 sq. ft. in area. • 1.5 Hour approved for shutter doors in vertical shaft openings not exceeding 152 sq. ft. in area. • .75 Hour approved for roll up storm shutters in corridor or room-partition opening not exceeding 152 sq. ft. in area. • 1.5 Hour approved for doors in exterior wall opening not exceeding 152 sq. ft. in area.
The Auto Smoke Fire-Storm® IMB insulated hurricane fire shutter is a combination of the features of Alpine’s Redi-Storm®® and Fire-Tite® roller doors models. It is Dade County Approved for high wind loads (up to 187 mph) as well as UL and MEA approved for fire protection. These roll up storm shutters come in galvanized or stainless steel and in a variety of different finishes.
Fire-Storm® curtains for these fusible link shutters are constructed of 2 3/4″ flat steel slats, and can be finished with powder coating or baked enamel finishes. All of these roller doors are equipped with a 22 gauge steel hood formed to fit the contour of the end brackets and durable ductile iron windlock with 1/4″ semi-solid rivets. Our door supports and brackets are all steel plates no less than 1/4″ thick. Alpine’s Torsion Counterbalance Assembly is state of the art, providing maximum security and ease of use. Choose the Alpine operator that best fits your needs.