Smoke Fire-Storm® Flat - Wind Rated Smoke Fire Door
Product Features
- High quality fire coded doors designed to prevent the spread of smoke
- Perimeter smoke seals standard
- UL rated doors and approved for stainless steel fire doors
- Oversize UL label up to 56’x30′
- Windstorm doors built in accordance with the requirements specified by Underwriters Laboratories Inc.
Alpines Fire-Storm® Doors are widely used in locations where there exists high winds and high levels of stormy weather activity. Throughout the Florida Coastline and many other coastal locations the Alpine Fire-Storm® doors have proven successful in protecting both people and property from injury do to flying debris.
Functional Benefits
- Alpine Fire-Storm® Doors are effective, strong and come in flat interlocking slat.
- Designs with perimeter smoke seals.
- Doors can be manually pushed up, hand-crank, hand-chain or motor operated.
- All operators can be adapted to specific conditions.
- Slide locks as a standard are provided.
- Alpine rolling steel doors are durable, sturdy and economical to install and maintain.
The Alpine Advantage and Benefit
- Alpine Fire-Storm® Doors are designed for easy operation and are trouble free with minimal maintenance required.
- After 50 plus years in business, Alpine doors have been proven reliable for use on thousands of installations in Commercial and Business locations. Alpine’s quality and workmanship is well known throughout the door industry. Our hands-on approach to every job ensures customer satisfaction.
- Made-to-Order manufacturing process. Alpine builds your product to the exact size, specifications and requirements.
- All of our products are constructed to have a rigid and compact design which provides for a more structural grade product while reducing overhead space and obstruction.
- Alpine builds trust by providing our products with a one-year warranty on material and workmanship. As we also offer an optional five-year prorated warranty.
- We are an ISO 9001:2015 registered firm which ensures that our products are built with strict quality control you can count on.
Installation
- The opening preparation and the installation of the fire door shall be performed in strict compliance with NFPA-80.
- Opening preparation, miscellaneous or structural metal work, access doors, finish or field painting, field electrical wiring, wire, conduit, fuses and disconnect switches are in the Scope of Work of other divisions or trades.
CURTAIN
Constructed of Interlocking, roll-formed 2.75” galvanized flat slats, Structural Quality Grade D per ASTM-A653/A653-M as standard.
Material Options: Stainless Steel or Aluminum
Finish Options: Tan, White or Grey; or ExoShield™ Powder Coating.
> Click here for available Powder Coating colors.
Ductile Cast iron, hot-dipped galvanized endlocks/windlocks are riveted to the ends of the slats with 1/4” rivets. Option in brass material which prevents sparking. Furnish windlocks based on wind load specifications.
BOTTOM BAR
Two galvanized roll-formed steel or structural steel angles which are designed to reinforce the bottom of the curtain. Equipped with rubber astragal or a sensing edge which extends into the guides. Galvanized steel as per ASTM-A653/A653-M
Option: Exo-Shield™ Powder coating to match curtain.
BRACKETS
ExoShield™ powder coated grey carbon steel plate not less than 1/4” thick with ball bearings at rotating support points on drive bracket. When bolted to the wall, the mounting angle that supports the barrel/pipe assembly and forms an end enclosure. OPTION: Stop lock bearing which prevents the door from free falling in the event of a drive operation failure.
GUIDES
Alpine’s Guide system is designed using structural steel angles with a minimum thickness of 3/16” meeting the ASTM A36 Standard that are bolted together with ⅜” fasteners in 1-¼ ” slotted connections bolted at a minimum 24” on center. One inch spacing of the guide channel ensures smooth operation. Vinyl clip on guide weather seal is standard.
SPRING COUNTERBALANCE
Pipe shall be manufactured with a diameter and wall thickness to restrict maximum deflection to 0.03” per foot of door width. Springs are helical torsion type which are designed to include an overload factor of 25% for optimum ease of operation., The springs are grease packed and mounted on a cold rolled steel inner shaft. Spring tension is adjustable from the outside of the end bracket. Sealed ball bearings as described above are designed to prevent wear on the shaft at each end of the pipe/barrel. Life Cycle: 20,000 up to 400,000
HOOD Hexagon (Option: Square or Round)
Made from #22-gauge galvanized steel as standard and formed to fit the contour of the end brackets. Optional material in stainless steel or aluminum. Equipped with a neoprene air baffle. Finish Options: #4 stainless steel or powder coated to match curtain.
LOCKING
Option 1: Slide bolt locks on the bottom bar.
Option 2: Cylinder locks. (Electric interlocks are recommended for motorized doors to prevent damage.)
Option 3: Motor acts as lock.
HOT DIPPED GALVANIZING (OPTION)
Applied to the guides, brackets and gears in addition to Standard Specifications. Applied where conditions of extreme or unusual atmospheric contamination is present. As per ASTM-A123.
(Pipe Shafts available with Zinc Enriched Powder Coating or Stainless-Steel)
FASCIA (OPTIONAL)
Useful where the area behind the hood is open, as seen in a between jambs type mounting configuration or other condition that exposes the opposite of coil side. Especially applicable with pre-engineered buildings. Finish is to match curtain.
Choice of hand chain, hand-crank, or motor operation.
Alpine Motor Operators
> View Redi-Master® Details
> View Redi-Hoist™ Details
> View Redi-Lift® Details
> View Redi-Tube™ Details
> View Redi-Shut™ Details
SAFETY ENTRAPMENT PROTECTION
Option: Electric Monitored Sensing edge with a coil cord.
Option: Redi-Reverse™ Light Curtain consists of a 6’0” high light curtain integral to the guides, left and right. If an object passes through the light curtain during the close cycle, the door will reverse to the open cycle and come to rest upon reaching the open limit.
Option: Photo safety sensors mounted to the guides 6” above the finished floor that project an infrared beam across the width of the door. Breaking the beam while the door is in motion will result in the immediate stop of downward travel and reverse the door to reopen to the top limit.
Access Controls
Optional control stations are available as Push Button Control Station or Key Control Stations. Special Control Stations are also available, please consult factory.
> Click for Access Control Details
These are the operator options for Smoke Fire-Storm® security door. Please see our entire line of service door operators. Alpine’s security door operator is UL 325 standard and constructed with the highest quality material and the latest in technical innovation. This ensures that each roll up door motor exceeds the requirements it is meant to achieve. Alpine is sure to have an operator that will meet all your individual specifications.
Contact Alpine to learn more about these motor operators today!
Smoke Fire-Storm® Flat Slat Doors
Advanced Windstorm Resistant Fire Doors
Below you will find comprehensive drawing details for our Windstorm Doors, Flat Slat Doors, Storm Doors, Rolling Storm Doors featuring important operation details for using hand chain, hand crank, or motor operation. The AutoCAD drawings and AutoCAD details comply with 08360, 08400 & 08330 construction specs for commercial doors and industrial doors. The drawing details available for Alpine’s Smoke Fire-Storm® also have several mounting options, including face mounted to steel, masonry, or between jamb mounted.
Alpine, manufacturer of Smoke Fire-Storm® flat slat doors are non-insulated commercial doors and industrial doors that are designed to prevent the spread of smoke. They are 3 hour approved for Windstorm Doors, Flat Slat Doors, Storm Doors, Rolling Storm Doors in dividing fire walls with openings no exceeding 120 sq. ft. in area. These windstorm doors are Dade County approved for high wind loads and Underwriters Laboratories Inc. approved for fire protection.
To download Details for the Windstorm Doors, Flat Slat Doors, Storm Doors, Rolling Storm Doors (PDF), please click below.
> For CAD Drawings, please click here
- Face Mounted to Masonry
- Face Mounted to Steel
- Between Jamb Mounted
- Not available but may be mounted to I-beam or steel tubes
The Smoke Fire-Storm® AutoCAD drawing and AutoCAD detail are for commercial doors informational purposes. They may change at any time. The CAD detail drawings reflect the options of industrial doors that are available to the architects and engineers compiling an AutoCAD drawing to present to contractors. The AutoCAD detail and AutoCAD drawing will be updated regularly. Alpine’s Windstorm Doors, Flat Slat Doors, Storm Doors, Rolling Storm Doors are built to last.
Alpine’s Engineering team will help you determine the exact windstorm doors and flat slat doors that will meet your specifications and requirements. Alpine will guide you through every step with your storm doors. Alpine will design industrial doors, commercial doors and rolling storm doors that will bring years of usage.
Alpine, manufacturer of windstorm doors, rolling storm doors are tough enough to stand up to a lot of usage. These flat slat doors are built to last. Call Alpine today to find out which Windstorm Doors, Flat Slat Doors, Storm Doors, Rolling Storm Doors are right for your building.
Alpine® Direct Mfg of windstorm doors and flat slat doors, Storm Doors, Rolling Storm Doors. Our priority is to manufacture high quality rolling doors, commercial doors and industrial doors.
Disclaimer: All data provided on this website is to be used for information purposes only, and is subject to change without prior notice. Alpine shall not be liable for technical or editorial errors or ommisions contained herein, nor for direct, incidental, consequential or any other damages resulting from furnishing, performance, or use of this information, even if Alpine Overhead Doors, Inc. has been advised of the possibility of such damages in advance. See the additional disclaimer in our Terms of Use.
Smoke Fire-Storm® Leakage Rated Door
Windstorm Resistant Smoke Doors
> Download 3 Part Specifications (PDF)
> Download 3 Part Specifications (DOC)
Model WIND-TITE®
Flat Slats
Warehouse Security Doors
NOTE: For leakage rated door specifications, architects must choose from a variety of options. The standard choice will be shown first in plain text followed by the options shown in [brackets] (Example “Finish: Galvanized [Powder coated] [Baked enamel]”). The specifier must make the appropriate choices and delete the others (Example: “Finish: Powder coated”).
GENERAL
1.01 SUMMARY OF UL RATED DOORS
A. This section includes: [Manual] or [Electric] operated, automatic closing, Windstorm Resistant Overhead Rolling Fire Door.
1. Successfully tested by Architectural Testing Institute (ATI) under Dade County protocols PA 201, PA 202, and PA 203 for a design load of + 60 psf.
2. Provide doors with Underwriter’s Laboratories, Inc. (UL) and Underwriter’s Laboratories of Canada (ULC) label for the fire rating classification. [4 hr.], [3 hr.], [1 ½ hr.], or [3/4 hr.] UL and ULC approved doors to be in accordance with both fire and windstorm resistant standards.
3. Design doors to withstand a windload of + 60 psf, 1.5 safety rating (Dade County equivalent to a normal +90 psf rating) for doors up to 20’8” x 30’. Provide compatible analysis certified by a Florida professional engineer for doors over 20’8” x 30’.
4. Manufacturer of storm doors must be capable of providing certified Net Vertical and Net Horizontal reaction forces imposed on door jambs.
5. Quality manufacturer listed by the Texas Department of Insurance’s Windstorm Resistant Construction Guide and the Texas Windstorm Insurance Association Building Code for Windstorm Resistant Construction.
6. Cycle life: Design doors of standard construction for normal use of 10,000 cycles standard [up to 400,000 cycles].
7. Manually resetable drop out mechanism with optional release devices. (For automatically resetable doors see specs for Auto Fire-Storm®)
B. Related Sections: Related to this section, but not limited to, the following (based on Master Format 2004):
1. Section 01660 – Product Storage and Handling Requirements.
2. Section 04220 – Concrete Unit Masonry.
3. Section 05120 – Structural Steel.
4. Section 06100 – Rough Carpentry.
5. Section 08310 – Access Doors and Panels.
6. Section 08710 – Door Hardware.
7. Section 09290 – Gypsum Board.
8. Section 09900 – Paints and Coatings.
9. Section 26000 – Electrical.
10. Section 28310 – Fire Detection and Alarm.
1.02 REFERENCES FOR LEAKAGE RATED DOOR
A. ASTM A 653/A 653M – Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
B. ASTM A 36 – Standard Specification for Carbon Structural Steel, Hot Rolled Steel
C. ASTM A 123 – Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products
D. ASTM A 312 – Standard Specification for Seamless, Welded, and Heavily Cold Worked Austenitic Stainless Steel Pipes
E. ASTM A 240 – Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications
F. ASTM A 276 – Standard Specification for Stainless Steel Bars and Shapes
G. ASTM A 31 – Standard Specification for Steel Rivets and Bars for Rivets, Pressure Vessels
H. ASTM A 449 – Standard Specification for Quenched and Tempered Steel Bolts and Studs
I. ASTM E 330 – Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference
J. Dade County PA-201, PA-202, PA-203: Large Missile Impact Test, Cyclic Wind Pressure Test, and Uniform Static Air Pressure Test
K. ASCE 7-93 – Standard Minimum Design Loads on Buildings and Other Structures
1.03 SUBMITTALS
A. Submit under provisions of Section 01300.
B. Product Data: Provide manufacturer’s standard details and catalog data. Provide installation instructions.
C. Shop Drawings for storm doors: Furnish shop drawings for architect’s approval. Include elevation, sections, and details indicating dimensions, materials, finishes, conditions for anchorage and support of each door.
D. Submit manufacturer’s recommended operation, troubleshooting, and maintenance instructions.
1.04 QUALITY ASSURANCE OF UL RATED DOORS
A. Manufacturer: Rolling doors shall be manufactured by a firm with a minimum of five years experience.
B. Fire-Rated Assemblies: Provide all doors with fire resistance rating required to comply with governing regulations which are inspected, tested, listed and labeled by UL, complying with NFPA 80 for class of opening. Provide UL label permanently fasted to each fire door assembly. Door shall be tested under UL10B and ULC10B, and provided with a [4 hour] [3 hr.] [1 ½ hr.] [3/4 hr.] rating. Also Factory Mutual and NY MEA approved.
C. Single-Source Responsibility: Manufacturer shall provide doors, tracks, motors, and accessories for each type of door. Secondary components shall come from a source acceptable to the manufacturer of the primary components.
1.05 DELIVERY, STORAGE, AND HANDLING
A. Deliver materials in original packaging supplied by manufacturer with intact labels. Store materials away from harmful environmental conditions and construction.
1.06 WARRANTY OF LEAKAGE RATED DOOR
A. Door Warranty: Provide one year written warranty from date of installation against deficiencies due to defects in materials or workmanship. Installer agrees to repair or replace any defects in materials or workmanship.
B. Project Warranty: Refer to Conditions of the Contract for project warranty provisions.
PART 2 – PRODUCTS
2.01 MANUFACTURER
A. Manufacturer of storm doors: Alpine Overhead Doors, Inc.; 8 Hulse Road Suite 1S, East Setauket, NY 11733. Telephone 800-257-4634 or 631-473-9300. Fax 631-642-0800.
B. Model: SMOKE FIRE-STORM® Windstorm Resistant Air Leakage Rated Rolling Fire Door
2.02 MATERIALS FOR UL RATED DOORS
A. Curtain:
1. Slats: Constructed of interlocking, roll-formed 2 ¾” flat slats. (For insulated slats see specs for Fire-Storm® IMB)
a) Material:
i) Galvanized steel, G90 coating exterior (G60 interior), Structural Quality Grade C, as per ASTM A 653/ A 653 M
Finish: Galvanized [Powder coated] [Baked enamel] (Minimum coating conforming with Coating Designation G-01 is required)
– OR –
ii) ASTM 240 Stainless steel 300 series
Finish: [Mill finish #2B] [#4 satin finish]
b) Gauge: (Per manufacturer’s standard)
i) Doors up to 20’8” wide: Minimum 21 gauge as manufacturer standard [20, 18, 16 gauge].
ii) Doors up to 12’ wide: Minimum 22 gauge [20, 18, 16]
2. Endlocks and Windlocks:
a) Ductile cast iron, hot-dipped, galvanized endlocks riveted to each end of each slat with four Semi-tubular, Mushroom Head ¼” rivets to prevent lateral movement and to limit slat deflection and bending stress. [Windlocks are dependent on windload and increase resistance to curtain jamming]
3. Bottom Bar: Two roll formed steel angles of minimum 2”x2”x1/8”, designed to reinforce curtain bottom. (Size dependent on dimensions per manufacturer’s standard)
a) Material:
i) Galvanized Steel as per ASTM A 653/ A 653 M
Finish: Gray shop prime [Powder Coated] [Baked Enamel]
– OR –
ii) ASTM 240 Stainless Steel 300 Series
Finish: [Mill finish #2B] [#4 satin finish]
b) Bolting of storm doors:
i) 20’8” wide: ¼” bolts at 15” o.c.
ii) 12’ wide: ¼” bolts at 20” o.c.
c) Weather Stripping: Rubber astragal bolted between bottom angles (Dade County Approved).
B. Guides for Leakage Rated Door:
1. Guides shall be designed using structural steel angles with a minimum thickness of 3/16”, minimum 1 ¼” slotted connections, and removable bellmouth curtain stops to allow for curtain maintenance without removal of guides. Bellmouth stops shall be flush with guide groove.
a) Angles:
i) 20’8” wide: Wall angle 3 ½ x 3 ½ x 7/16”, inside angle 2 ½ x 2 ½ x 3/8”, outside angle 4 x 3 x ¼”.
ii) 12’ wide: Wall angle 2 ½ x 3 ½ x ¼”, inside angle 2 x 2 ½ x ¼”, outside angle 3 x 3 3/16” min
b) Bolting:
i) 20’8” wide: Minimum 5/8” bolts at no more than 9” o.c.
ii) 12’ wide: Minimum 1/2” bolts at no more than 15” o.c.
c) Material:
i) ASTM A 36 Carbon Structural Steel
Finish: Gray shop prime coat [ASTM A 123 Galvanized] [baked enamel paint] [powder coated].
– OR –
ii) ASTM 276 Stainless Steel 300 Series
Finish: [Mill finish #2B] [#4 finish satin]
2. Smoke Seal: 1 ½” brush smoke gaskets.
C. Door Support Brackets and Mounting Plates:
1. Steel plate not less than 1/4” thick. Provide ball bearings at rotating support points. Bolt plates to wall mounting angles with minimum 1/2″ fasteners. Plate supports counterbalance assembly and forms end enclosures.
a) Material for UL Rated Doors:
i) ASTM A 36 Carbon Steel:
Finish: Gray shop prime coat [ASTM A 123 Galvanized] [Baked enamel paint] [Powder coated].
– OR –
ii) ASTM 240 Stainless Steel 300 Series
Finish: [Mill Finish #2B]
D. Counterbalance Assembly for storm doors: Torsion
1. Counterbalance assembly: Steel pipe barrel of a size capable of carrying a curtain load with a maximum deflection of 0.03” per foot of door width. Heat-treated helical torsion springs encased in a steel pipe and designed to include an overload factor of 25% to ensure minimum effort to operate. Sealed and prelubricated high speed ball bearing at rotating support points. Torsion spring charge wheel for applying spring torque and for future adjustments.
a) Material:
i) ASTM A 36 Carbon Structural Steel
Finish: Gray shop prime coat [A 123 Hot-Dip Galvanized]
– OR –
ii) A 312 Stainless Steel 300 Series Finish: Mill finish
b) Life Cycle: High Cycle springs designed to satisfy 10m through 400m life cycles. Consult engineering if height exceeds width for any cycle above 20m. (Cycle defined as one time opening and closing of door)
E. Hood of Leakage Rated Door:
1. 24 gauge steel. Formed to fit the contour of the end brackets with reinforced top and bottom edges. Provide support bracing for doors wider than 20 feet at every 10 feet to prevent excessive sag. Fasten with minimum ¼” bolts at 10” o.c.
2. Shape: Hexagon [square] [round]
3. Material:
a) Galvanized Steel as per ASTM A 653/ A 653 M
Finish: [Baked enamel paint] [Powder coated]
– OR –
b) ASTM 240 Stainless Steel 300 Series:
Finish: [Mill finish #2B] [#4 satin finish]
4. [Fascia]: Galvanized [Stainless Steel], provided where areas behind door hood are open. Materials and finish same as hood.
5. Smoke Seal: Lintel 2” brush seal.
F. Locking for UL Rated Doors:
1. Provide padlockable slide locks for latching and locking door on coil side bottom bar at each jamb extending into slots in guides. (Electric Interlocks recommended with motorized doors only)
2. Manual chain hoist: Provide padlockable chain keeper on guide.
2.03 OPERATION:
A. Opening/Closing: Manual push-up [Manual hand chain] [Manual hand crank] [Motor Operator].
B. Automatic closure for storm doors is activated by fusible link [Fire Door Release Device].
C. [Manual hand chain]:
1. Provide chain hoist operator with endless steel chain, chain pocket wheel and guard, geared reduction unit, and chain keeper secured to guide.
D. [Manual hand crank]:
1. Provide crank hoist operator including crank gear box, steel crank drive shaft and geared reduction unit. Fabricate gear box to completely enclose operating mechanism and be oil-tight.
E. [Motor Operators]:
1. Choose ONE:
a) Medium-Duty, Alpine® Model Redi-Hoist™ driven by efficient V-belt primary drive with chain/sprocket secondary. Maximum ½ hp. For use on doors up to 10’ x 10’.
– OR –
b) Industrial-Duty, Alpine® Model Redi-Lift™ driven by heavy-duty V-belt with chain/sprocket secondary reduction. Optional auxiliary chain hoist. Maximum 1 hp. For use on doors up to 12’ x 12’.
– OR –
c) Heavy Industrial-Duty, Alpine® Model Redi-Master™ driven by heavy-duty worm gear in oil bath reduction. Standard auxiliary chain hoist. Standard ½ hp (maximum 3 hp)
2. [Sensing Edges] (For double angle bottom bar): For motorized doors, sensing edges allow door to go up in case of obstruction. [Pneumatic Edge] [Electric Edge] [Wireless Edge].
a) Colors: Gray [Yellow] [Black] [White] [Yellow with black stripes]
F. Release Devices:
1. Fusible link with chain system:
a) Activation: Melting of fusible link at 165° Fahrenheit. When automatic closing is activated, chain shall disengage causing door to close.
b) Closing speed controlled by Integral Oscillating governor [Viscous governor].
c) Average closing speed: No less than 6” per second and not more than 24” per second as per NFPA 80 Section 6, paragraph 4.1.5.
2. [Redi-Release™ Release Devices]: Electric Fail-Safe devices used in conjunction with fusible link. [Smoke detector] Choose ONE from either standard models or SS class:
a) Class 1: Manually operated system that can be tied into most fire alarm systems.
– OR –
b) Class 2: All the features of Class 1, with the additional capability to allow motor operation. If operator is chosen, an electrical edge is recommended.
– OR –
c) Class 3: All the features of Class 2 with the addition of standard Alpine Control Panel and Standard Electric Safety Edge. Allows door to automatically go up in case of an obstruction.
– OR –
d) Class 4: All the features of Class 3 with the addition of the Alpine Uninterrupted Power Supply (Battery backup) that is self-activating during a power outage.
– OR –
e) SS Class Model A: Includes independently adjustable delays of 10 seconds on alarm activations (10 sec. max. adjust) and 10 seconds on power loss (30 sec. max. adjust) with a hold/release rating of 40 lbs.
f) SS Class Model B: All the features of model A with:
i) The hold open/release device shall recognize that the door is in the closed position and where motor driven, be capable of sensing that power is available to the motor. The device may be wired to close on alarm.
ii) [Audible and visual annunciators]: To operate during alarm closing cycle.
g) SS Class Model B2: All the features of model B with:
i) 72-hour battery backup with low/no battery logic sounder.
ii) Sounder/Strobe annunciator: To sound during closure due to alarm or power loss.
h) SS Class Model C: All the features of model B2 with:
i) Bottom bar sensing edge.
ii) Remote test plate.
2.04 Mounting of Leakage Rated Door:
1. Interior face mounted on prepared opening.
2. Interior mounted between jambs and under lintel in a prepared opening.
3. Exterior face mounted on prepared opening.
2.05 Fire Ratings for UL Rated Doors:
1. Underwriter’s Laboratories:
Doors are constructed to conform within requirements specified by Underwriters Laboratories, Inc. (UL) and Underwriter’s Laboratories of Canada (ULC). Doors are automatic and self-closing, Class (A) (B) (C) (D) or oversized certificate.
4 hour – Approved for doors with openings not exceeding 162 sq. ft. in area.
Class (A) – 3 hour approved for doors in dividing fire walls with openings not exceeding 120 sq. ft. in area
Class (B) – 1 ½ hour approved for doors, in vertical shaft openings not exceeding 120 sq. ft. in area.
Class (C) – ¾ hour approved for doors in corridor or room-partition opening not exceeding 120 sq. ft. in area.
Class (D) – 1 ½ hour approved for doors in exterior wall opening not exceeding 120 sq. ft. in area.
The oversize Certificate is authorized for rolling steel doors for the protection of openings in fire walls, vertical shafts, and exterior walls where the area exceeds 120 square ft., or for openings in the above locations when width or height exceeds 12 ft. The maximum dimensions for doors for standard fire protection provided with the
Oversize Door Certificate are not to exceed 56 ft. in width and 24 ft. in height.
2. Factory Mutual.
3. New York Materials, Equipment and Acceptance Division (MEA).
PART 3 – EXECUTION
3.01 EXAMINATION
A. Verify that dimensions are correct and project conditions are in accordance with manufacturer’s installation instructions; do not proceed with installation until unacceptable conditions have been corrected.
3.02 INSTALLATION OF LEAKAGE RATED DOOR
A. Install storm doors in accordance with manufacturer’s instructions.
B. Ensure that units are installed plumb and true, free of warp or twist, and within tolerances specified by manufacturer for smooth operation.
C. Preparation for opening and installation of fire door to be in strict compliance with NPFA-80.
3.03 FIELD TESTING
A. Test doors for regular operation and automatic closing. Proper authorities having jurisdiction must witness test and sign Drop Test Form.
3.04 DEMONSTRATION OF UL RATED DOORS
A. Instruct the Owner’s personnel in correct operation and maintenance of units.
3.05 ADJUST AND CLEAN
A. Clean units in accordance with manufacturer’s instructions.
B. Restore slight blemishes in finishes in accordance with manufacturer’s instructions to match original finish. Remove and provide new units where repairs are not acceptable to the Architect.
Disclaimer: All data provided on this website is to be used for information purposes only, and is subject to change without prior notice. Alpine shall not be liable for technical or editorial errors or omissions contained herein, nor for direct, incidental, consequential or any other damages resulting from furnishing, performance, or use of this information, even if Alpine Overhead Doors, Inc. has been advised of the possibility of such damages in advance. See the additional disclaimer in our Terms of Use.
Alpine® Redi-Release®
For Use with Fire-Tite®, Fire-Shut® and Fire-Storm® Doors
The Solid State Securities time delay fire door release device is an optional feature for your fire resistant doors. Alpine® Redi-Release® is normally energized as a fail-safe device for fire doors, and incorporates state of the art electronic security control circuitry.
The Redi-Release series release devices are the ideal safety option for fire resistant doors. These devices are able to respond to emergency conditions generated by manual or automatic initiating devices that are normally closed, and are designed to be used in conjunction with a temperature fuse link system. The Test-Release device features include time delay on alarm and power loss, motor voltage sensing, form C output, proximity/door edge input and trouble diagnostic capabilities. Check model label to be installed to verify applicable features.
CAUTION: As with all releasing device systems, maximum fire protection is provided when installed in accordance with factory specifications and used with fuse link systems. Fail-safe operation can only be provided when input power is applied.
LiftMaster Professional
For Motorized Doors – Electro-Mechanical Operators
The AFCB fire door release device is designed to be used in conjunction with a standard commercial door operator to provide a fully automated door closing system. For use with motorized doors incorporating a reversing electric safety edge. This 120VAC device can power up to four smoke detectors and two horn/strobes or speaker/strobes. This system combines state-of-the-art functionality and advanced features typically found on special-order fire door operators.
LM21AFCB – Download Owners Manual
- UL864 Revision 9 compliant
- Programmable DIP switch delay setting – either 10, 20, 30 or 60 seconds delay of door release to permit passage clearance
- Internal battery backup system
- Motor voltage sensing monitors voltage to the operator and activates a mechanical door release upon loss of power to the operator.
- Obstruction cycling – works in conjunction with the door’s electrical safety edge, reversing the door if an obstruction is encountered
- Test keyswitch – permits floor-level testing of the system
Non-Motorized Doors
The XP fire door release device provides a fail-safe release mechanism for non-motorized doors and acts as an interface between the door and the fire alarm system. The device required 24VDC power from an approved UL1481 regulated power supply with battery backup, such as a fire alarm control panel. Therefore, installation will require coordination with a fire panel installer.
LM21XP Download Owners Manual
- UL864 Revision 9 compliant
- Programmable DIP switch delay setting – either 10, 20, 30 or 60 seconds delay of door release to permit passageway clearance
- Close door detection – prevents door release if the door is kept in the closed position and eliminates door reset service calls or potential system damage
- On board diagnostic – LEDs for early troubleshooting
- Testing function – allows routine fire door testing without requiring activation of the central alarm system; easy reset function returns the device to a standby state
Non-Motorized Doors with Battery Backup Option
Versatility allows the XPBB fire door release device to operate on 120VAC, 24VAC or 24VDC power sources. Internal battery backup allows the release device to stand alone from the fire alarm system and act independently in the event of a power outage. The system can provide 24VDC power for up to four smoke detectors and two horn/strobes, mounted on either side of the door. Programmable delay settings, close door detection, diagnostic LEDs, localized testing, and reset capabilities are also standard.
LM21XPBB Download Owners Manuals
- UL864 Revision 9 compliant
- Programmable DIP switch delay setting – either 10, 20, 30 or 60 seconds delay of door release to permit passageway clearance
- Inputs for normally open – 2-wire or 4-wire detectors and 4-wire normally closed detectors
- On board diagnostic – LEDs for early troubleshooting
- Trouble and alarm relays – for communication with the fire alarm control panel, if required
- Audible trouble sounder – to indicate when the release device is not operational
- Testing function – allows routine fire door testing without requiring activation of the smoke detector
Contact us today to find out which Alpine® solution is right for you!
3 Hour approved for fire coded doors in dividing fire walls with openings not exceeding 120 sq. ft. in area. • 1.5 Hour approved for leakage rated doors in vertical shaft openings not exceeding 120 sq. ft. in area. • .75 Hour approved for windstorm doors in corridor or room-partition opening not exceeding 120 sq. ft. in area. • 1.5 Hour approved for UL rated doors in exterior wall opening not exceeding 120 sq. ft. in area.
The Fire-Storm® leakage rated door is a combination of the features of Alpine’s Redi-Storm®® and Fire-Tite® models. These fire coded doors are Dade County approved for high wind loads (up to 187 mph). These are also UL rated doors and MEA approved for fire protection. These windstorm doors with a smoke label comes in galvanized or stainless steel and in a variety of different finishes. Choose the Alpine operator that best fits your needs.
Fire-Storm® leakage rated door curtains are constructed of 2 3/4″ flat steel slats, and can be finished with powder coating or baked enamel finishes. Each of the windstorm doors are equipped with a 22 gauge steel hood formed to fit the contour of the end brackets and durable ductile iron windlock with 1/4″ semi-solid rivets. Our fire coded doors have supports and brackets that are all steel plates no less than 1/4″ thick. Alpine’s Torsion Counterbalance Assembly is state of the art, providing maximum security and ease of use. Our UL rated doors are top of the line.
2 3/4″ Flat Slat